A light tower runs four LED lamps for ten hours, unattended, in a place with no power. Lead-acid does not survive the duty for long; a sodium pack makes a battery-only tower practical.
What a tower draws
| Lamp set | Draw | 10 h shift |
|---|---|---|
| 4 × 100 W LED | 400 W | 4 kWh |
| 4 × 200 W LED | 800 W | 8 kWh |
| 4 × 320 W LED | 1.3 kW | 13 kWh |
How to size the pack
1. Shift energy. Lamp kW × hours. That is the pack’s usable requirement.
2. Divide twice. By 0.8 usable depth, then by the derating at the site’s coldest design temperature.
3. Recharge. A battery tower has to recharge during the day. If the site has no supply and no sun, a generator or a swap pack is the only option.
Why a battery tower instead of a generator
No fuel delivery, no refuelling visits, no idling noise at night — and no diesel theft. The trade is capital cost and a charge cycle that has to fit into the working day.
Cold and unattended
Discharge works to −30 °C and below, so a tower left on a winter site can still light. Charging is the limit, and a solar-assisted tower in winter will charge slowly until temperatures rise.
Where it is not worth it
Mains available. A cable is cheaper than any battery for a long-duration site.
A fixed site. Towers pay where the site moves.
Questions buyers ask
How many hours per charge?
Ten hours is the usual design target; winter sites often accept eight.
Can solar keep up?
In summer, with a large array. In winter, rarely — plan on mains or generator charging.
What about diesel theft?
That is one of the main reasons towers go battery-only on remote sites.
Can one pack serve two towers?
Only as a swap pack. Sizing for two towers doubles the pack.