A light tower runs four LED lamps for ten hours, unattended, in a place with no power. Lead-acid does not survive the duty for long; a sodium pack makes a battery-only tower practical.

0.4–1.3 kWtypical lamp load
4–13 kWhper ten-hour shift
Unattendedno refuelling, no noise
−30 °Cdischarge; charging needs warmth

What a tower draws

Lamp set Draw 10 h shift
4 × 100 W LED 400 W 4 kWh
4 × 200 W LED 800 W 8 kWh
4 × 320 W LED 1.3 kW 13 kWh

How to size the pack

1. Shift energy. Lamp kW × hours. That is the pack’s usable requirement.

2. Divide twice. By 0.8 usable depth, then by the derating at the site’s coldest design temperature.

3. Recharge. A battery tower has to recharge during the day. If the site has no supply and no sun, a generator or a swap pack is the only option.

Why a battery tower instead of a generator

No fuel delivery, no refuelling visits, no idling noise at night — and no diesel theft. The trade is capital cost and a charge cycle that has to fit into the working day.

Cold and unattended

Discharge works to −30 °C and below, so a tower left on a winter site can still light. Charging is the limit, and a solar-assisted tower in winter will charge slowly until temperatures rise.

Where it is not worth it

Mains available. A cable is cheaper than any battery for a long-duration site.

A fixed site. Towers pay where the site moves.

Questions buyers ask

How many hours per charge?

Ten hours is the usual design target; winter sites often accept eight.

Can solar keep up?

In summer, with a large array. In winter, rarely — plan on mains or generator charging.

What about diesel theft?

That is one of the main reasons towers go battery-only on remote sites.

Can one pack serve two towers?

Only as a swap pack. Sizing for two towers doubles the pack.