Pack thermal check

How much heat a pack makes at a given load, and how much air or coolant it takes to hold the temperature rise you can live with.

Home / Pack thermal check

Every cell has an internal resistance. Push current through it and the losses come out as heat: I²R per cell. A 280 Ah cell at 0.35 mΩ and 150 A of pack current is already dissipating watts — multiply by the number of cells in the pack and it becomes the number that decides whether you need a fan or a cold plate.

Heat (W) = (Ipack ÷ P)² × Rcell × cells
Airflow (m³/h) = Heat ÷ (1.2 × 1.005 × ΔT) × 3.6

Inputs

A

Continuous current, not the peak the BMS allows for a few seconds.

P
cells

16 cells = a 16S1P pack. Take the number from the pack configuration tool if you have just built one.

mΩ

From the datasheet at 25 °C. Sodium-ion cells run 0.3–1.5 mΩ for prismatic, higher for cylindrical. Resistance climbs in the cold — typically 50–100% higher at −20 °C. Use the datasheet figure if it gives a cold value.

Cooling target
°C
°C

Cell temperature above ambient. 10–15 °C keeps the pack in its comfort zone; above 20 °C the cycle life starts to pay for it.

Heat and cooling

—

 

  • Cell current—
  • Heat per cell—
  • Pack heat—
  • Cooling needed—
  • Pack runs at—
  • Verdict—

Rules of thumb, not a CFD result. Air figures assume 1.2 kg/m³ and 1.005 kJ/kg·K with the whole flow passing the cells; liquid assumes water-glycol at 3.9 kJ/kg·K. Real enclosures leak air, cells sit in a stack and the middle rows run hotter than the edges — add 30% to the flow if the pack is sealed or the cells are tight together.