Pack configuration calculator

Pick a cell, set the voltage and capacity you need — get the series/parallel count, cell quantity, energy, weight and the BMS rating that follows.

Home / Pack Configuration Calculator

Series sets the voltage, parallel sets the capacity. A 16S pack of 3.2 V cells lands at 51.2 V; the parallel count is whatever gets you to the amp-hours. Round up, never down — a pack that misses its voltage target will not talk to the inverter.

Series = Target V ÷ Cell V · Parallel = Target Ah ÷ Cell Ah · Energy = V × Ah

Inputs

From the cell database — 62 cells.

V
Ah
A

Used to check the C-rate against the cell’s continuous rating.

Resulting pack

—

 

  • Configuration—
  • Cells needed—
  • Pack voltage—
  • Pack capacity—
  • Energy—
  • Cell weight only—
  • C-rate at load—
  • BMS—

Voltage uses the cell’s nominal figure from its datasheet; a fully charged pack sits about 15% higher, so check the inverter’s maximum input. Weight is cells only — enclosure, busbar, BMS and hardware typically add 25–45%.