Battery runtime and charge time

How long a pack runs a load — and how long a charger takes to put the energy back. Same inputs, two answers.

Home / Battery Runtime Calculator

Discharge is energy divided by the load. Charge is the same energy divided by what the charger can push in — which is why a pack that runs for eight hours takes four hours or fewer to refill.

Runtime (h) = Capacity (Wh) × DoD × η ÷ Load (W)
Charge time (h) = Capacity (Wh) × DoD ÷ (Charger A × V × ηcharge)

V

Used to convert Ah ↔ Wh. A 16S sodium pack is 51.2 V; a 4S pack is 12.0 V.

A

50 A into a 314 Ah pack is 0.16C — a sensible charge rate. Sodium-ion cells usually accept 0.5C, power cells up to 1C.

Usable capacity & losses
%

How much of the pack you plan to use. 90% is typical for storage; 100% shortens cycle life.

%

Inverter and wiring losses. A DC load is closer to 97%; an AC load through an inverter is usually 90–94%.

Estimated runtime

90% usable capacity

—

 

  • Energy—
  • Load current—
  • Usable energy—
  • C-rate—

An estimate, not a guarantee: real runtime falls with cold temperature, cell age, high discharge rate and inverter standby draw. Sodium-ion keeps more of its capacity below 0 °C than LFP, but the pack still loses usable energy in the cold.