Aluminium-case prismatic cells from 20 Ah to 352 Ah. These are the cells behind most stationary storage cabinets, telecom strings and traction packs, because they pack volume efficiently and accept a compression stack that holds preload over life.
Two things decide whether a prismatic build works. The stack needs preload — commonly around 300 kgf per cell face — held across thousands of cycles, not just at assembly; a stack that loses it will fade without any BMS fault. And heat has further to travel in a large cell, so the cooling path has to be designed rather than assumed above about 1C.