Price on request — quoted per configuration, quantity and Incoterm.Ask for a price →
A 220 Ah prismatic sodium-ion cell for stationary storage and backup. The datasheet is explicit about the cold-charge window: no charging at or below −10 °C or at or above 45 °C, and 0.20C between −30 °C and 0 °C, while discharge remains permitted to −30 °C.
Send the duty cycle and we will confirm the module, busbar and compression design around it.
Capacity
220 Ah
Nominal voltage
3.0 V
Chemistry
Sodium-ion (Na-ion)
Form
Prismatic, aluminium case
Charge cut-off voltage
3.95 V
Discharge cut-off voltage
1.50 V
Standard charge
0.50C CC to 3.95 V, then CV to 0.05C
Standard discharge
0.50C to 1.50 V
Charge temperature
Above −10 °C and below 45 °C
Charge rate in cold
≤0.20C between −30 °C and 0 °C
Discharge temperature
−30 to +60 °C
Application
Utility and C&I storage, telecom backup
Datasheet, declarations and warranty terms for this model.
These figures are quoted by order type rather than per part number, because the same cell can ship from stock or start a new tooling project. If your quantity sits between two rows, the smaller one applies until a change is needed.
Minimum order quantity
Sample evaluation
1 unitA single piece, so you can test the chemistry and the fit before committing to a batch.
Standard catalogue item
5–10 unitsThe stocked line: cells, cases and components that need no change before shipping.
New ODM design
100–200 setsNew structure, new BMS protocol or new housing tooling. The batch size covers the setup work.
Large project
quoted per projectContainer-scale and framework agreements are quoted against the schedule, not against a unit price.
Production lead time
Stock item
3–5 working daysShipped from stock once the order is confirmed.
OEM (silk print, label, packaging only)
15–20 working daysSame structure and same BMS. Only the marking and the packaging change.
New ODM (new structure, BMS protocol, housing, diesel-to-electric)
30–35 working daysCounted from specification freeze, not from the enquiry.
Adding a certification
+15–30 daysOn top of the production time above. The laboratory sets the schedule, not us.
Shipping transit is quoted separately and starts after production finishes. We do not publish a transit figure, because it depends on the forwarder, the route and the season — ask for it with the order and we will quote the current rate.
Questions buyers ask
What voltage and capacity does this come in?
3.0 V nominal, 220 Ah capacity. The figures are the ones on the specification table on this page, not a range across the family.
What temperature range does it operate in?
−30 to +60 °C. That is the discharge window. Charging has its own limits, given as Above −10 °C and below 45 °C on this page, and the BMS thresholds have to match the cell data rather than a generic default.