A poultry house is a ventilation system with birds in it. If the fans stop on a hot night, the loss is measured in the whole flock — which is why a battery sits behind the controller.
What has to stay running
| Load | Draw | Priority |
|---|---|---|
| Tunnel / side fans | 2–15 kW | Critical in heat |
| Controller and sensors | 50–200 W | Critical |
| Alarm dialler / SMS | 10–30 W | Critical |
| Feed augers and lighting | 1–5 kW | Deferrable |
Two different jobs
Controller and alarm backup needs only a small pack for a few hours of warning. Fan backup needs a large pack and, in reality, a generator — a battery cannot hold a 15 kW fan bank for long. Being clear about which job the battery does is what keeps the project honest: many backup systems are alarm systems with a large label.
How to size it
1. Decide the job. Warning time (controller + alarm) or cooling time (fans).
2. Warning time. 200 W for four hours is 0.8 kWh — a small pack and the most valuable purchase.
3. Cooling time. 10 kW of fans for one hour is 10 kWh, which is generator territory, not battery territory.
Ammonia and dust
Poultry houses are corrosive. The battery enclosure needs to handle ammonia vapour, which rules out some plastics and all exposed terminals. A sealed box with a sealed connector is the baseline.
Where it does not pay
A farm with an auto-start generator. A small battery for the controller is enough.
A shed with natural ventilation. No fans, no problem.
Questions buyers ask
Can it run the fans for hours?
Only a small fan bank. Ten kilowatts is a generator duty, and a battery that claims otherwise is a warning system.
What temperature range?
The pack sits in the shed: −10 to 45 °C is common. Discharge is fine; charging in a hot shed needs derating.
How often should it be tested?
Monthly with the alarm test, and annually on load. A pack that fails silently is worse than none.
Is it safe near livestock?
With a sealed enclosure and no exposed terminals. Ammonia attacks connectors, so inspect annually.