Skip to content
New product 12 V 100 Ah sodium-ion truck starting battery, 1500 CCA, Group 31T See the launch →

Livestock and Poultry House Battery — Ventilation Backup

Home / News and Blog / Livestock and Poultry House Battery — Ventilation Backup
Livestock and Poultry House Battery — Ventilation Backup
16 Nov 2026

A poultry house is a ventilation system with birds in it. If the fans stop on a hot night, the loss is measured in the whole flock — which is why a battery sits behind the controller.

2–15 kWfan load, the hard part
50–200 Wcontroller and alarm
Ammoniacorrodes unprotected electronics
Minutesoften all a battery can buy

What has to stay running

Load Draw Priority
Tunnel / side fans 2–15 kW Critical in heat
Controller and sensors 50–200 W Critical
Alarm dialler / SMS 10–30 W Critical
Feed augers and lighting 1–5 kW Deferrable

Two different jobs

Controller and alarm backup needs only a small pack for a few hours of warning. Fan backup needs a large pack and, in reality, a generator — a battery cannot hold a 15 kW fan bank for long. Being clear about which job the battery does is what keeps the project honest: many backup systems are alarm systems with a large label.

How to size it

1. Decide the job. Warning time (controller + alarm) or cooling time (fans).

2. Warning time. 200 W for four hours is 0.8 kWh — a small pack and the most valuable purchase.

3. Cooling time. 10 kW of fans for one hour is 10 kWh, which is generator territory, not battery territory.

Ammonia and dust

Poultry houses are corrosive. The battery enclosure needs to handle ammonia vapour, which rules out some plastics and all exposed terminals. A sealed box with a sealed connector is the baseline.

Where it does not pay

A farm with an auto-start generator. A small battery for the controller is enough.

A shed with natural ventilation. No fans, no problem.

Questions buyers ask

Can it run the fans for hours?

Only a small fan bank. Ten kilowatts is a generator duty, and a battery that claims otherwise is a warning system.

What temperature range?

The pack sits in the shed: −10 to 45 °C is common. Discharge is fine; charging in a hot shed needs derating.

How often should it be tested?

Monthly with the alarm test, and annually on load. A pack that fails silently is worse than none.

Is it safe near livestock?

With a sealed enclosure and no exposed terminals. Ammonia attacks connectors, so inspect annually.

Where to go next

Products for this application

Industrial & traction 7 models · specs and sizes Lead-acid replacement 78 models · specs and sizes 24 V 160 Ah forklift sodium-ion battery — 9S, 4.1 kWh single product · full specification

Have a specification question this article does not answer? Send it with the numbers you already have.

Request a quote

Part of

More guides in this group