A fence energizer draws a tiny current for months in a field, with no mains and no supervision. That is a duty where battery choice decides whether the fence is still live in February.
What an energizer draws
| Energizer output | Draw | Pack that suits |
|---|---|---|
| 0.5 J | 50–100 mA | 12 V 20–40 Ah |
| 1–2 J | 150–300 mA | 12 V 60–100 Ah |
| 5 J+ | 500 mA+ | 12 V 100 Ah plus solar |
Most installations pair a small solar panel with the battery. The panel covers the average draw; the battery covers the nights and cloudy days.
Cold is the whole problem
At −15 °C a lead-acid block may deliver only part of its capacity, exactly when the solar input is also at its lowest. Sodium keeps more capacity at low temperature, so the same panel and battery size holds a fence through winter that a lead-acid set would not.
Charging in a field
A small panel through a controller set for the pack’s voltage window is the whole system. The controller, not the battery, is where most installations fail — a lead-acid setting will undercharge a sodium pack.
Where it does not pay
Where the fence is close to mains and the battery is a backup that never cycles, the cheapest block wins. Remote winter fencing is the case where the difference shows.