Campsite Power Pedestal — Sodium-ion Off-Grid Hook-Ups
16 Nov 2026

A campsite with no grid connection still has to offer a hook-up, or it cannot charge for a pitch. Trenching cable for twenty pitches is expensive; a battery pedestal with solar is often cheaper.

2–10 kWhper pedestal
0.3–4 kWhper pitch per day
Solarsized for the worst month
Tariffwhat pays back the pedestal

What one pitch draws

Pitch type Daily Pack per pedestal
Tent pitch, lights and phone 0.3–0.8 kWh 2 kWh
Campervan, fridge and lights 1–2 kWh 5 kWh
Motorhome with inverter 2–4 kWh 8–10 kWh

How to size the system

1. Occupancy. A pedestal is used most nights in summer and barely in winter. Size on summer demand and let the pack sit at partial charge in winter — which is where sodium is easier than lead-acid.

2. Array. Solar has to cover the daily draw in the shoulder season, plus losses. A 2 kW array for a 5 kWh pedestal is a reasonable starting point in mid-latitudes.

3. Peak. A kettle or a heater draws 1–2 kW regardless of daily energy. The inverter sizes on the peak.

What the site has to decide

Whether the pedestal is grid-fed with a battery buffer, solar with a battery, or a shared bank with distribution. Each has a different cost per pitch, and the tariff charged per night decides which one pays back.

Temperature and cycling

A pedestal cycles daily and sits outdoors in all weather. Sodium’s discharge window means no heater in winter, and its cycle life at shallow depth suits a duty where most nights draw only a fraction of the pack.

Where it does not pay

Grid already on site. A consumer unit per pitch is cheaper.

A very short season. Two months of use will not recover the capital.

Questions buyers ask

How many pitches per pack?

One pack per 1–3 pitches, depending on the pitch type and the tariff model.

What about metering?

An outlet meter per pitch, or a flat nightly charge. That is a commercial decision.

Can it run in winter?

The pack holds charge; solar output drops. Most sites close or run at reduced load.

Is it safe outdoors?

With sealed enclosures and RCD protection. The electrical design comes before the battery choice.