An off-grid system is a battery problem disguised as a solar problem: the array is sized for the worst month, and the battery is sized for the nights in that month.
Sizing, in order
| Step | What to use | Typical |
|---|---|---|
| Daily consumption | Measured, not estimated | 3–15 kWh |
| Autonomy | Days without sun | 2–3 days |
| Depth of discharge | Usable fraction | 80% |
| Cold derating | Capacity at the coldest design point | Divide, not multiply |
The last step is the one projects skip. A bank sized at 25 °C will not deliver the same autonomy at −30 °C, whatever the chemistry.
A worked example
A cabin uses 4 kWh a day. Three days of autonomy is 12 kWh. At 80% depth that is 15 kWh of nominal pack. If the coldest design point costs 20% of capacity, the bank becomes 18.75 kWh — nearly 19 kWh, not 12.
That is why the same cabin “needs” very different packs depending on who sized it.
Why sodium for a cold site
Discharge to −40 °C means the bank does not need heating to work through a winter night. Charging still needs the cells above their charge floor, which in practice means charging once the day has warmed the enclosure, or accepting a reduced rate in the coldest hours.
Generator hours
Most off-grid systems keep a generator. Sodium accepts a high charge rate in one block, so generator runs can be short and efficient instead of long and partial — the cheapest generator hour is the one you do not run.
Where LFP is cheaper
A heated plant room. In mild climates with a controlled room, an LFP bank of the same capacity is lighter and slightly more efficient.
Very small systems. Under a few kWh, the price difference rarely justifies a change of chemistry.
Questions buyers ask
Can I charge at −10 °C?
Not at full rate. The cells have a charge floor; below it the BMS blocks current until the pack warms.
How big should the array be?
Size for the worst month’s daily consumption plus the battery’s round-trip losses, then add margin for panel soiling and age.
Do I still need a generator?
Most off-grid sites keep one for winter. Storage reduces its hours rather than removing it.
What about summer overproduction?
The controller curtails it. Over-panelling for winter is normal; the surplus is simply not harvested.