A tug spends most of its time waiting and a few minutes at full power alongside a ship. That duty — long idle, then an enormous current — is where a battery either works or becomes a maintenance item.
What the duty looks like
| Operation | Power | Duration |
|---|---|---|
| Transit to berth | 200–600 kW | Minutes |
| Bollard pull | 1–3 MW | Minutes |
| Standby | 10–50 kW | Hours |
High rate is the requirement
This is not an energy-density application, it is a power application. The pack has to deliver megawatts for short windows and cool down afterwards, which puts the thermal design ahead of the cell capacity.
Salt and water ingress
Everything on deck corrodes. Battery rooms on tugs need positive pressure, sealed penetrations and marine-grade hardware — the same engineering as any enclosed space, with worse air.
Where sodium is the wrong answer
For a tug that works continuously at high power, a purpose-built high-rate system or hybrid with a generator is more suitable. Harbour craft with long standby and short bursts are the case.