Shuttle Bus and People Mover Battery — Sodium-ion Packs

Home / News and Blog / Shuttle Bus and People Mover Battery — Sodium-ion Packs
Shuttle Bus and People Mover Battery — Sodium-ion Packs
16 Nov 2026

A shuttle runs the same route all day at low speed, stops constantly and returns to the same bay. That duty is gentler on the motor than highway work and much harder on the battery than most operators expect.

48–96 Vby vehicle class
5–40 kWhpack range
Depot windowthe real constraint
Frequent stopsthe load that sizes the pack

What the vehicles need

Vehicle Voltage Pack Daily distance
Resort / campus shuttle (6–14 seats) 48 V / 72 V 10–20 kWh 80–150 km
Sightseeing cart (4–8 seats) 48 V 5–10 kWh 50–100 km
Airport people mover 72 V / 96 V 20–40 kWh Fixed loop

How to size the pack

1. Route energy. Low-speed shuttles use roughly 0.10–0.18 kWh/km with passengers; a 120 km day is 12–20 kWh.

2. Stops are the load. Repeated acceleration from zero draws high current, and regenerative braking puts some back. Size on the peak and check the continuous rating, not the average.

3. Depot window. Divide daily energy by the hours available and by the charger’s capability. If the window is short, charge rate decides the pack, not distance.

Depot charging in a fixed window

Most fleets charge overnight in one bay with a limited supply. Sodium accepts a high charge rate, so the same connection fills more vehicles in the same window — the practical argument in a depot where adding a charger means upgrading the supply.

Cold mornings and heating

Shuttles start before dawn in winter and the cabin heater draws from the pack. The winter range figure is therefore a function of heating as much as chemistry, and route planning should use the winter number.

Where it does not pay

A single shuttle on a short route. With an overnight charge and cheap power, the change rarely closes.

Long-distance coach work. Energy density and fast charging favour LFP or NMC.

Questions buyers ask

Can we charge more vehicles on the same supply?

Yes, because the pack accepts a higher rate. The charger and supply still cap the total.

How much range in winter?

Less, mostly because of cabin heating. Plan with the winter figure, not the summer one.

Do we need to change the charger?

Yes, or reprogram it. The existing unit is almost certainly set for lead-acid or an older lithium profile.

Is regen braking a problem?

No, but the pack’s charge acceptance limit at low temperature is. In freezing weather regen must be limited by the BMS.

Where to go next

Products for this application

Industrial & traction 7 models · specs and sizes 24 V 160 Ah forklift sodium-ion battery — 9S, 4.1 kWh single product · full specification

Have a specification question this article does not answer? Send it with the numbers you already have.