Underground equipment runs hard in heat and dust, charges in a confined space, and cannot be towed out easily. Battery choice here is an availability decision, not an environmental one.
What the equipment needs
| Equipment | Voltage | Duty |
|---|---|---|
| Electric scoop / LHD | 80 V+ | Very high continuous |
| Drill rig | 48 V / 80 V | High, intermittent |
| Ventilation and pumping | 48 V | Continuous |
| Personnel carrier | 48 V | Moderate |
Heat is the enemy underground
Ambient in a deep mine can exceed 40 °C, and the equipment adds its own heat. Derating for ambient is not optional: a pack quoted at 25 °C will not deliver its rated current at 45 °C, and the BMS should reflect that.
Dust and charging
Dust ingress into a connector is a fire risk in any battery system. Sealed connectors and a charging bay with positive pressure are the practical controls. Sodium’s higher thermal runaway threshold helps the risk assessment but does not remove the requirement.
Where it does not pay
Small operations with diesel equipment and no ventilation constraints should not convert for the sake of it. Confined, hot operations with ventilation costs are where the case exists.