A forklift battery is bought on two numbers: the shift it has to survive, and the hours it takes to recharge. Sodium changes the second one, which is why it fits multi-shift warehouses better than a straight lead-acid swap.
Truck brands and the voltages they use
| Brand | Common series | Typical voltage | Lead-acid block |
|---|---|---|---|
| Toyota | 8FBE, 8FB, Traigo | 24 V / 48 V / 80 V | 2 V cells in a steel tray |
| Hyster | J, E, S series | 36 V / 48 V / 80 V | 2 V cells |
| Crown | FC, SC, RC | 24 V / 36 V / 48 V | 2 V cells |
| Linde | E14–E50, H series | 48 V / 80 V | 2 V cells |
| Yale | MP, GDP, ERP | 48 V / 80 V | 2 V cells |
| Jungheinrich | EFG, ETV, EJE | 24 V / 48 V / 80 V | 2 V cells |
| Mitsubishi / CAT | FB, 2ET | 48 V / 80 V | 2 V cells |
| Clark | C, GTS, TMX | 24 V / 48 V / 80 V | 2 V cells |
| Doosan / Daewoo | B, BR, D series | 48 V / 80 V | 2 V cells |
| Hangcha / Heli / EP | CPD, CPDB | 48 V / 80 V | 2 V cells |
Industrial traction packs are built as 2 V cells in series inside a steel tray, counterweighted to replace the lead they replace. A sodium pack is lighter for the same energy, so the tray needs a ballast plate rather than a straight drop-in — that is a design detail we settle before quoting.
What changes and what stays
| Stays | Changes | |
|---|---|---|
| Truck | Motor, controller, hydraulics | Traction cut-off and gauge behaviour |
| Tray | Steel tray and lid | Ballast plate, cell spacers, busbar |
| Charging | Charger location | Profile, or the charger itself |
| Connector | DIN / Euro connector | Only if the pack spec differs |
How to size the pack
1. Shift energy. Measure or estimate the kWh a truck uses per shift. A 2-tonne counterbalance doing mixed work commonly runs 8–15 kWh per shift; a reach truck in a tall rack runs more.
2. Opportunity charging. If the truck charges at breaks, the pack only has to cover the longest unbroken stretch, not the whole shift. That is what lets a smaller pack replace a big lead-acid block.
3. Usable depth. Divide by 0.8 for a sensible design point, then check the pack’s continuous discharge rating against the truck’s hydraulic pump, which draws far more than traction.
Charging and the shift pattern
A lead-acid truck needs a full charge and a cooling period; a sodium pack accepts partial charges through the shift, which is what lets one truck cover two shifts without a battery change. The charger, not the pack, usually sets the limit — a legacy charger with a lead-acid profile will undercharge the pack and the truck will feel slow by mid-shift.
Cold stores
In a freezer warehouse the pack works at −25 °C. Discharge is fine; charging is not, and the cell must be above its charge floor before current is accepted. Charging in a warm bay, or heating the pack, is the practical answer — the BMS enforces the limit either way.
Where a sodium pack is the wrong purchase
Single-shift operations. With a cheap tariff and a calendar-based replacement, the payback on any lithium-family pack is slow.
Very high continuous loads. An 80 V truck on constant heavy duty may favour a purpose-built traction pack over a general-purpose one.
No room for ballast. If the tray cannot take a counterweight plate, a lighter pack changes the truck’s stability envelope and that is the manufacturer’s decision, not ours.
Questions buyers ask
Can I keep the existing charger?
Only if its profile can be reprogrammed to the pack’s voltage window. A fixed lead-acid profile will not terminate correctly.
Will the truck’s display still work?
If it reads voltage, it will be misleading. Most fleet conversions add a shunt or a CAN interface so the operator sees real state of charge.
How much weight do I save?
A 48 V 600 Ah lead-acid traction block weighs well over a tonne. The sodium pack of similar usable energy is a fraction of that, which is why ballast is part of the design.
Can it work in a freezer?
Yes for discharge, with a charge floor. Charging below the cell’s cut-off temperature must be prevented or the pack must be warmed.
Do you supply the connector?
Yes, to the truck’s standard — DIN or Euro on most European fleets. Send the connector type with the enquiry.