On a set, a generator is loud, smells, and cannot be in frame. A cart battery solves all three, provided it can carry the load through a shooting day.
What a cart powers
| Load | Draw | Duration |
|---|---|---|
| Camera, monitors, recorder | 300–800 W | All day |
| DIT station and drives | 500–1,500 W | All day |
| LED lighting | 1–3 kW | Per setup |
| Sound and comms | 200–500 W | All day |
How to size the pack
1. Add the cart load. Camera, monitors and DIT together are commonly 1–2 kW.
2. Multiply by the shooting day. Ten hours at 1.5 kW is 15 kWh — which is why carts use a rotation rather than one large pack.
3. Plan the rotation. Two 8 kWh packs allow one to charge while the other works, which fits most small-unit days.
Why silence changes the plan
With a generator, the shooting day is organised around when it can run. With a battery cart, the camera can move to a location the generator could never serve — a stairwell, a rooftop at dawn, a chapel.
Charging between setups
A two-pack rotation is the usual arrangement: one on the cart, one charging. Sodium’s charge acceptance shortens the swap window, which matters when the AD is waiting.
Where it does not pay
Big lighting rigs. They still need generators; the energy is beyond a cart.
Studio work. Mains is available and cheaper.
Questions buyers ask
How much can one cart carry?
Practical carts run 5–10 kWh, enough for a department or two on a ten-hour day.
Is it really silent?
The inverter has a fan, but there is no engine noise or exhaust — which is what matters on set.
Can it be charged on location?
From mains where available, or from a generator during a break. A rotation makes the charge window less critical.
What about cold locations?
Discharge is fine; charging needs the pack above its floor, so charge indoors overnight.