
Shipping batteries is a paperwork problem until it is a fire problem. Sodium-ion changes one variable in that equation: cells can be brought to 0 V and transported in that state, which is not a condition a lithium cell tolerates well.
What actually happens at 0 V
In a lithium cell, deep discharge dissolves the copper current collector on the anode side and can plate metal in places that create internal shorts when the cell is recharged. A lithium cell stored at very low voltage is a stored risk.
Sodium cells use aluminium collectors on both sides. Aluminium does not alloy with sodium at low potential, so a cell taken to 0 V does not dissolve its own current path. Capacity after re-activation depends on the cell design, and the supplier should show the recovery curve rather than promise full capacity.
What this changes for freight
Sodium cells and packs still have their own UN numbers, and they are still regulated dangerous goods in most jurisdictions — typically UN3551 for cells and UN3552 for packs. Shipping at 0 V changes the state of charge argument, not the classification.
In practice, what improves is the risk assessment: a consignment at 0 V cannot deliver energy into a fault, which simplifies the carrier conversation and the warehouse storage rules.
Storage and state of charge
For long storage, the general rule holds for any chemistry: keep the cell away from the voltage extremes, store cool and dry, and record the date. A sodium cell tolerates a wider window than lithium, but a year at 45 °C still costs capacity.
Re-activation needs a proper charge profile. Slowly bring the cell back at low current while watching for abnormal heating, and treat a cell that will not accept charge as suspect rather than forcing it.
Where this is not a licence to be careless
Zero volts is a transport advantage, not a safety guarantee. A mechanically damaged cell, a cell heated far above its rating, or a pack with a failed BMS is still a hazard.
Ask for the transport documents that will accompany the shipment, the UN number that applies to your product form, and the state-of-charge declaration. Those three documents decide whether the container moves or sits at the port.
This is not theoretical: a 200 Ah prismatic sodium cell in current production is specified as dischargeable to 0 V, and returns to service after a standard charge.
Where to go next
- Cells we ship with 0 V transport documentation
- UN38.3 and what travels with a consignment
- Ask us about a shipment
Questions we get asked about this
Can sodium cells really be shipped at 0 V?
Yes, cells can be brought to 0 V for transport, and the aluminium current collectors do not dissolve as copper does in a deep-discharged lithium cell.
Does 0 V make shipping unregulated?
No. Sodium cells and packs still fall under their own UN entries, typically UN3551 and UN3552. Transport documents are still required.
How much capacity comes back after 0 V storage?
It depends on the cell design. Ask the supplier for the re-activation curve rather than a percentage — the recovery varies with time at 0 V and temperature.

