
Cycle life is not one number per chemistry, and our own quoted figures show why. One test stand, one end-of-life criterion of 80% state of health, five different results.
| Cell | Test condition | Cycles |
|---|---|---|
| 0.9 Ah high-rate cylindrical | 1C charge / 1C discharge, 25 ± 2 °C | 1,000 to 85% |
| 7 Ah pouch | 0.5C, 25 ± 2 °C, 1 N·m stack torque | 2,000 |
| 18 Ah cylindrical | 0.5C, 25 ± 2 °C | 3,000 |
| 55 Ah prismatic | 0.5C charge and discharge | 4,000 |
| 20 Ah cylindrical | 0.5C / 0.5C, 80% SOH | 1,500 minimum |
Read down the table and the pattern is mechanical rather than chemical: the harder you cycle and the smaller the cell, the sooner it fades. A 1C high-rate cell asked to survive 4,000 cycles is being asked for something its electrode design does not offer. A 55 Ah prismatic at 0.5C is being asked for something it does.
Compare claims only at the same conditions
Rate, end-of-life criterion and temperature have to match before two numbers can be compared. Most datasheets state the first two and omit the third, which is why two suppliers can appear to disagree by a factor of three while both are telling the truth about different tests.
What the curve looks like
Capacity does not fall off a cliff at the rated cycle count. It declines slowly, then faster, and where the knee sits depends on depth of discharge and temperature. A pack designed to stop at 80% state of health lasts far longer than one run to 70%, which is why the system design, not the datasheet, decides the replacement date.
If a project needs 6,000 cycles
The answer is usually a larger cell run at a lower rate rather than a better chemistry. Doubling the cell capacity halves the C-rate for the same load, and lower rate is the single largest lever on cycle life.
Measure it: cycle a sample at your own duty for 200 cycles and compare the fade rate with the claim. Two weeks of testing settles an argument that datasheets cannot.
Where to go next
Questions we get asked about this
How many cycles does a sodium battery last?
From 1,000 on a 0.9 Ah high-rate cell at 1C to 4,000+ on a 55 Ah prismatic at 0.5C. The rate and the cell size move the number more than the chemistry label.
Does depth of discharge matter?
Yes. Cycling 20–80% gives substantially more total cycles than 0–100%, and it is where daily storage duty is designed.
How do I verify a claim?
Ask for the capacity-versus-cycle curve and the protocol, then cycle a sample at your own duty for 200 cycles and compare the fade rate.

