A gate opener or a camera on a pole runs a 12 V backup battery that stays at float for years and has to work once, in the rain, at −10 °C. Small SLA blocks fail that duty quietly.
What these systems need
| Device | Pack | Duty |
|---|---|---|
| Sliding gate opener | 12 V 7–18 Ah | Float, occasional high current |
| Swing gate opener | 12 V 7–12 Ah | Float |
| CCTV camera + NVR | 12 V 18–50 Ah | Continuous small load |
| Access control panel | 12 V 7–20 Ah | Float |
How to size the pack
1. Standby load. A camera and NVR draw 10–30 W, so a four-hour hold-up is 40–120 Wh — a 12 V 10 Ah pack covers it.
2. Surge. Gate motors pull 10–20 A for two seconds. The pack must deliver that even after months at float.
3. Cabinet temperature. A metal cabinet in the sun reaches 50 °C. Derate for it, because that cabinet is what ages the pack.
Why the SLA block dies
An SLA battery on permanent float at 25 °C loses capacity through grid corrosion; at 40 °C in a metal cabinet it happens faster. After two or three years the door opens slowly or not at all, and the battery is the last thing anyone checks.
What sodium changes
Wider ambient tolerance and no need for heating in a cold cabinet, plus a BMS that can report state of health before the door stops working. The trade is that the charging circuit has to be set for the pack’s voltage window — an older opener with a fixed 13.8 V supply may not reach it.
Where it is not worth it
A cheap SLA block on a maintenance contract. Replaced yearly, it changes nothing.
Indoor access control. A stable 22 °C room does not stress any chemistry.
Questions buyers ask
Will the opener’s charger work?
Only if its float voltage fits the pack. Many openers use a fixed 13.8 V supply that will not fully charge a 12.8 V pack.
How long will it last?
Calendar life at cabinet temperature. A 50 °C cabinet costs far more than a 25 °C one.
Can it report a fault?
With a BMS that has communication. Without it, the first warning is a gate that will not open.
Is one pack enough for a camera and NVR?
Size on the combined load and the hold-up time you need, plus a margin for ageing.