Most sodium cells in the merchant market come from a few factories and reach buyers through intermediaries. The cell is often fine; batch control is where quality disappears.
Documents before samples
Ask for the datasheet with test conditions, the batch record for the lot you are buying, and the transport documents. A brochure and a price is not a record.
Then ask which factory made the cell. A name and a line number beats “our partner factory”.
Four numbers on a sample
Capacity at 0.5C and 25 °C, internal resistance, first-cycle efficiency, and self-discharge after two weeks. Together they separate a genuine cell from a sorted one.
If capacity matches but resistance is 20% high, the cell is aged or the tabs are poor, and the pack will derate earlier than the datasheet claims.
Batch consistency
Buy two lots a quarter apart and compare capacity histograms rather than averages. Process control shows up as a tight distribution.
The average hides the tail, and the tail is what fails in a series string.
Red flags
A price well below market with no explanation. A datasheet without test conditions. A grade-A claim without a batch record. Certificates naming another model.
The cheapest reliable test is 100 cycles at your own duty. Two weeks answers what email cannot.
Compare like with like
A 0.9 Ah high-rate cell quoted at 1,000 cycles and a 55 Ah prismatic quoted at 4,000 are not competitors — they are different products. When two suppliers disagree by a factor of three, one of them is quoting a different rate, a different end-of-life criterion or a different temperature.
Where to go next
Questions we get asked about this
What should I test on a sample?
Capacity at 0.5C, internal resistance, first-cycle efficiency and two-week self-discharge.
How do I check batch consistency?
Buy two lots a quarter apart and compare capacity histograms rather than averages.