36V100: a sodium-ion pack built to the footprint of the sealed lead-acid block it replaces — 3840 Wh in a plastic case.

Specification

  • Model: 36V100
  • Nominal voltage: 38.4 V
  • Capacity: 100 Ah
  • Energy: 3840 Wh
  • Voltage range: 30–43.2 V
  • Maximum continuous discharge current: 100 A (1C)
  • Rated charge current: 75 A (0.5C)
  • Pack size: 480 × 231 × 170 mm
  • Weight: ≈26.2 kg
  • Operating temperature: −20 to +55 °C
  • Cycle life: 3000 cycles
  • Series / parallel: No series, max 2P
  • Bluetooth: Optional
  • Shell material: Plastic
  • Chemistry: Sodium-ion (Na-ion)
  • Cell type: Sodium-ion (Na-ion)
  • Cells used: BW 60145 / DFD 60150 / DFD 60130
  • Application: Lead-acid replacement

Why sodium-ion

No lithium and no cobalt in the cell, usable capacity down to −20 °C, no sulphation if it is left flat for a season, and 3000 cycles at pack level. It mounts where the lead-acid block sat and uses the same terminal positions.

What it is for

UPS, alarm and access control, emergency lighting, mobility scooters, golf carts and small solar systems. Tell us the charger you already have and we will confirm the BMS cut-off.

Specification

36V100 — 36 V 100 Ah sodium-ion pack — specification
Nominal voltage38.4 V
Capacity100 Ah
Energy3840 Wh
Voltage range30–43.2 V
Maximum continuous discharge current100 A (1C)
Rated charge current75 A (0.5C)
Pack size480 × 231 × 170 mm
Weight≈26.2 kg
Operating temperature−20 to +55 °C
Cycle life3000 cycles
Series / parallelNo series, max 2P
BluetoothOptional
Shell materialPlastic
ChemistrySodium-ion (Na-ion)
Cell typeSodium-ion (Na-ion)
Cells usedBW 60145 / DFD 60150 / DFD 60130
ApplicationLead-acid replacement

Ordering: MOQ and lead time

These figures are quoted by order type rather than per part number, because the same cell can ship from stock or start a new tooling project. If your quantity sits between two rows, the smaller one applies until a change is needed.

Minimum order quantity

Sample evaluation 1 unit A single piece, so you can test the chemistry and the fit before committing to a batch.
Standard catalogue item 5–10 units The stocked line: cells, cases and components that need no change before shipping.
New ODM design 100–200 sets New structure, new BMS protocol or new housing tooling. The batch size covers the setup work.
Large project quoted per project Container-scale and framework agreements are quoted against the schedule, not against a unit price.

Production lead time

Stock item 3–5 working days Shipped from stock once the order is confirmed.
OEM (silk print, label, packaging only) 15–20 working days Same structure and same BMS. Only the marking and the packaging change.
New ODM (new structure, BMS protocol, housing, diesel-to-electric) 30–35 working days Counted from specification freeze, not from the enquiry.
Adding a certification +15–30 days On top of the production time above. The laboratory sets the schedule, not us.

Shipping transit is quoted separately and starts after production finishes. We do not publish a transit figure, because it depends on the forwarder, the route and the season — ask for it with the order and we will quote the current rate.

Questions buyers ask

What voltage and capacity does this come in?

38.4 V nominal, 100 Ah capacity, 3840 Wh of energy. The figures are the ones on the specification table on this page, not a range across the family.

What are the dimensions?

480 × 231 × 170 mm. Check the mounting space against this figure rather than against the catalogue photo, because the enclosure adds wall thickness on every side.

How much does it weigh?

≈26.2 kg. For freight the packed weight is higher: crating and pallet add to this figure, so ask for the shipping weight when you book.

What temperature range does it operate in?

−20 to +55 °C. That is the discharge window. Charging has its own limits, and the BMS thresholds have to match the cell data rather than a generic default.

What cycle life is quoted?

3000 cycles. A cycle figure only means something with its rate, temperature and end-of-life criterion, which is why we quote the condition next to the number instead of a bare count.

What continuous current can it take?

100 A (1C). Size the cable and the busbar to this current with margin, and check that the BMS in your build is rated at least as high.

Request a quote Ask an engineer Preview the datasheet