Skip to content
New product 12 V 100 Ah sodium-ion truck starting battery, 1500 CCA, Group 31T See the launch →
Home / Products / Packs / Industrial & traction / 48 V 160 Ah forklift sodium-ion battery — 17S1P, 7.7 kWh
48 V 160 Ah forklift battery

48 V 160 Ah forklift sodium-ion battery — 17S1P, 7.7 kWh

Brand: Polytone
Part number: 48V160Ah
Nominal voltage: 48.4 V
Nominal capacity: 160 Ah
Standard discharge current: 80 A
Cycle life: >5,000 cycles (25 °C, 0.5C, 70% DoD)
Availability: In stock
Price on request — quoted per configuration, quantity and Incoterm.Ask for a price →

48 V 160 Ah sodium-ion traction battery for electric forklifts. 17S1P, IP65, −40 to +60 °C, >5,000 cycles at 70% DoD. Sodium-ion cells in a steel case that drops into the compartment the lead-acid block came out of, with the BMS inside and no watering.

Why sodium-ion on a forklift

  • Wide discharge temperature — a cold store and a summer dock from the same pack.
  • High discharge power for the lift and drive motors together.
  • Long cycle life, quoted at pack level over 80% DoD.
  • No watering, no acid, no equalisation charge.
  • Low self-discharge, so a parked truck comes back with charge in it.

Specification

  • Model: 48V160Ah
  • Form: Traction pack for industrial vehicles
  • Chemistry: Sodium-ion (Na-ion)
  • Nominal voltage: 48.4 V
  • Nominal capacity: 160 Ah
  • Minimum capacity: ≥155 Ah
  • Rated energy: 7,700 Wh
  • Operating voltage range: 34.0–58.6 V
  • Fast-charge voltage: 58.6 ±0.2 V
  • Float charge voltage: 51.0–53.5 V
  • Low-voltage cut-off: 34.0–37.4 V
  • Standard charge current: 80 A
  • Recommended charge current: ≤80 A
  • Maximum charge current: 160 A
  • Standard discharge current: 80 A
  • Recommended discharge current: ≤80 A
  • Maximum discharge current: 300 A
  • Peak discharge current (3 s): 500 A
  • Internal resistance: ≤20 mΩ
  • Charge temperature: 0 to +55 °C
  • Discharge temperature: −40 to +60 °C
  • Cycle life: >5,000 cycles (25 °C, 0.5C, 70% DoD)
  • Cell configuration: 17S1P
  • IP grade: IP65
  • Weight: 125 ±10 kg
  • Dimensions: 730 × 400 × 350 mm
  • Packing dimensions: 780 × 450 × 430 mm
  • Low-temperature charging: Heating supported
  • BMS: Built in — state monitoring, fault protection, communication; 4G optional
  • Bluetooth: Supported
  • Application: Electric forklifts, warehouse trucks, industrial vehicles

SOC and OCV

25 °C discharge, 0.5P 25 °C charge, 0.5P
SOC OCV (V) SOC OCV (V)
100% 55.25 0% 39.10
90% 53.04 10% 47.77
80% 52.36 20% 50.66
70% 51.68 30% 51.68
60% 51.00 40% 52.36
50% 50.32 50% 52.70
40% 49.30 60% 53.04
30% 47.94 70% 53.38
20% 45.05 80% 53.72
10% 39.10 90% 54.57
0% 27.20 100% 56.10

Scope

Supplied assembled and tested, with the BMS set for the charger on site. Tell us the truck model and the charger voltage and we will confirm the connector and the cut-off before dispatch.

Specification

48 V 160 Ah forklift sodium-ion battery — 17S1P, 7.7 kWh — specification
FormTraction pack for industrial vehicles
ChemistrySodium-ion (Na-ion)
Nominal voltage48.4 V
Nominal capacity160 Ah
Minimum capacity≥155 Ah
Rated energy7,700 Wh
Operating voltage range34.0–58.6 V
Fast-charge voltage58.6 ±0.2 V
Float charge voltage51.0–53.5 V
Low-voltage cut-off34.0–37.4 V
Standard charge current80 A
Recommended charge current≤80 A
Maximum charge current160 A
Standard discharge current80 A
Recommended discharge current≤80 A
Maximum discharge current300 A
Peak discharge current (3 s)500 A
Internal resistance≤20 mΩ
Charge temperature0 to +55 °C
Discharge temperature−40 to +60 °C
Cycle life>5,000 cycles (25 °C, 0.5C, 70% DoD)
Cell configuration17S1P
IP gradeIP65
Weight125 ±10 kg
Dimensions730 × 400 × 350 mm
Packing dimensions780 × 450 × 430 mm
Low-temperature chargingHeating supported
BMSBuilt in — state monitoring, fault protection, communication; 4G optional
BluetoothSupported
ApplicationElectric forklifts, warehouse trucks, industrial vehicles

Ordering: MOQ and lead time

These figures are quoted by order type rather than per part number, because the same cell can ship from stock or start a new tooling project. If your quantity sits between two rows, the smaller one applies until a change is needed.

Minimum order quantity

Sample evaluation 1 unit A single piece, so you can test the chemistry and the fit before committing to a batch.
Standard catalogue item 5–10 units The stocked line: cells, cases and components that need no change before shipping.
New ODM design 100–200 sets New structure, new BMS protocol or new housing tooling. The batch size covers the setup work.
Large project quoted per project Container-scale and framework agreements are quoted against the schedule, not against a unit price.

Production lead time

Stock item 3–5 working days Shipped from stock once the order is confirmed.
OEM (silk print, label, packaging only) 15–20 working days Same structure and same BMS. Only the marking and the packaging change.
New ODM (new structure, BMS protocol, housing, diesel-to-electric) 30–35 working days Counted from specification freeze, not from the enquiry.
Adding a certification +15–30 days On top of the production time above. The laboratory sets the schedule, not us.

Shipping transit is quoted separately and starts after production finishes. We do not publish a transit figure, because it depends on the forwarder, the route and the season — ask for it with the order and we will quote the current rate.

Questions buyers ask

What voltage and capacity does this come in?

48.4 V nominal, 160 Ah capacity. The figures are the ones on the specification table on this page, not a range across the family.

What are the dimensions?

730 × 400 × 350 mm. Check the mounting space against this figure rather than against the catalogue photo, because the enclosure adds wall thickness on every side.

How much does it weigh?

125 ±10 kg. For freight the packed weight is higher: crating and pallet add to this figure, so ask for the shipping weight when you book.

What temperature range does it operate in?

−40 to +60 °C. That is the discharge window. Charging has its own limits, given as 0 to +55 °C on this page, and the BMS thresholds have to match the cell data rather than a generic default.

What cycle life is quoted?

>5,000 cycles (25 °C, 0.5C, 70% DoD). A cycle figure only means something with its rate, temperature and end-of-life criterion, which is why we quote the condition next to the number instead of a bare count.

Request a quote Ask an engineer Preview the datasheet

Full A4 datasheet, one page. We store the address to answer you — nothing else.