A 48 V 160 Ah sodium-ion battery in a 5U rack case, built for telecom base stations, equipment-room backup and rack-mounted storage. Sodium-ion cells, a built-in BMS and a standard 19-inch mounting face — it goes where the lead-acid string was and reports its own state.
Inside the case

What it does
Mains fails, the battery carries the site until the generator starts or the outage ends. The BMS watches cell voltage, current and temperature, trips the protection thresholds and reports over the site controller, so an operator sees a weak string before it drops a site. Bluetooth is available locally; 4G telemetry is optional.
Why sodium-ion for a base station
- Intrinsically safer. No lithium and no cobalt in the cell; the chemistry does not support the thermal runaway that takes a cabinet with it.
- −40 to +60 °C discharge. A cabinet on a pole in the sun, or an unheated shelter in the north, does not need a separate thermal design.
- Long cycle life. More than 3,000 cycles at 25 °C, 0.5C, 30% DoD — the duty a backup string actually sees.
- Lower lifetime cost. Maintenance-free, and the whole-life cost is quoted at more than 60% below the lead-acid string it replaces.
- Drop-in. 19-inch rack mounting, 48 V nominal, float and charge voltages compatible with the rectifier settings already on site.
Specification
- Model: 48V160Ah-5U
- Form: Rack-mount, 5U
- Chemistry: Sodium-ion (Na-ion)
- Nominal voltage: 51.3 V
- Nominal capacity: 160 Ah
- Minimum capacity: ≥155 Ah
- Rated energy: 8,200 Wh
- Operating voltage range: 36.0–62.1 V
- Fast-charge voltage: 62.1 ±0.2 V
- Float charge voltage: 54.0–56.7 V
- Low-voltage cut-off: 36.0–39.6 V
- Standard charge current: 80 A
- Recommended charge current: ≤80 A
- Maximum charge current: 200 A
- Standard discharge current: 80 A
- Recommended discharge current: ≤80 A
- Maximum discharge current: 300 A
- Peak discharge current: 300 A for 3 s
- Internal resistance: ≤20 mΩ
- Charge temperature: 0 to +60 °C
- Discharge temperature: −40 to +60 °C
- Cycle life: >3,000 cycles (25 °C, 0.5C, 30% DoD)
- Cell configuration: 18S1P
- IP grade: IP21
- Weight: 120 ±10 kg
- Dimensions: 815 × 482.6 × 222 mm (5U)
- Packing dimensions: 860 × 550 × 290 mm
- BMS: Built in — state monitoring, fault protection, communication; 4G optional
- Bluetooth: Supported
- Mounting: Standard 19-inch rack
- Application: Telecom base stations, equipment rooms, rack-mounted storage
SOC and OCV
| 25 °C discharge, 0.5P |
25 °C charge, 0.5P |
| SOC |
OCV (V) |
SOC |
OCV (V) |
| 100% |
59.40 |
0% |
43.20 |
| 90% |
57.96 |
10% |
48.24 |
| 80% |
56.52 |
20% |
51.12 |
| 70% |
55.44 |
30% |
52.92 |
| 60% |
54.36 |
40% |
54.72 |
| 50% |
53.28 |
50% |
46.16 |
| 40% |
51.84 |
60% |
57.42 |
| 30% |
50.04 |
70% |
58.50 |
| 20% |
46.80 |
80% |
59.58 |
| 10% |
38.70 |
90% |
60.66 |
| 0% |
27.00 |
100% |
62.10 |
Open-circuit voltage measured at 25 °C, 0.5P. The charge column is as supplied; the 50% reading (46.16 V) sits below the 40% reading, so treat this table as a reference rather than a curve.
Scope
Supplied with the rack ears and the terminal set. Tell us the rectifier voltage and the telemetry protocol on site and we will confirm the BMS settings before dispatch.
Datasheet, declarations and warranty terms for this model.
Open datasheet (print or save as PDF) →
Declaration of conformity and warranty statement are issued with the order. Ask for the current revision if your design is already frozen.