Polytone
Innovate. Grow. Advance.
Polytone Technology Co., Ltd.
Shenzhen, Guangdong, China
nacellpower.com
jayhan@okiatec.com · 0755-83202104
BMS datasheet

3S 100 A BMS — separate port, NCM thresholds, 87 × 35 × 8 mm

Part number PT-BMS-3S100-SP Brand Polytone Issued 9 Nov 2026
3S 100 A BMS — separate port, NCM thresholds, 87 × 35 × 8 mm
Charge voltage12.6 V
Size87 × 35 × 8 mm
Operating temperature-30 to +80 °C
Discharge current100 A

Overview

Slim 3S protection board, 87 × 35 × 8 mm, 100 A discharge on a separate port with a 12.6 V charge path. Thresholds are the ternary (NCM) set: 4.28 V over-charge, 2.55 V over-discharge, balancing from 4.18 V

Specification

Configuration3S (12 V)
Size87 × 35 × 8 mm
Discharge current100 A
Charge current100 A (separate port)
Charge voltage12.6 V
Main circuit resistance≤ 25 mΩ
Over-charge detect4.28 ± 0.05 V
Over-charge delay0.5 s
Over-charge release4.08 ± 0.1 V
Balance start4.18 ± 0.05 V
Balance current30 ± 5 mA
Over-discharge detect2.55 ± 0.1 V
Over-discharge delay0.1 s
Over-discharge release3.0 ± 0.1 V
Over-discharge current200 ± 30 A, 9 ms delay
Short circuit250 µs, release by disconnecting the load
Standby current< 50 µA
Operating temperature-30 to +80 °C
ApplicationE-bike, tricycle, low-speed EV, storage, solar inverter

Ordering

Minimum order quantity

  • Sample evaluation — 1 unit
  • Standard catalogue item — 5–10 units
  • New ODM design — 100–200 sets
  • Large project — quoted per project

Production lead time

  • Stock item — 3–5 working days
  • OEM (print, label, packaging) — 15–20 working days
  • New ODM — 30–35 working days
  • Adding a certification — +15–30 days
Polytone Technology Co., Ltd.
Floor 5, Block A & E, Donghaiwang Industrial District,
Longgang District, Shenzhen, Guangdong, China
nacellpower.com
jayhan@okiatec.com
+852 9593 9048 (WhatsApp)
Figures are as recorded for this model and are quoted for the stated test conditions. Cells and packs ship as Class 9 dangerous goods with UN 38.3 and MSDS documentation. Specifications may be revised without notice; confirm the current revision with our team before design freeze.